Electrically Stimulated Antagonist Muscle Contraction Increased Muscle Mass and Bone Mineral Density of One Astronaut – Initial Verification on the International Space Station

23 June 2021

    Introduction

    It is well known that atrophy of the musculoskeletal system due to disuse occurs among astronauts. For instance, atrophy of the muscles and bones of astronauts in weightlessness is evident [12]. Sarcopenia is widely used as one of the terms to express weakness and atrophy of the muscles, although it initially referred to atrophy due to aging. However this initial Sarcopenia has been classified as primary Sarcopenia, and all the other muscle weakness and atrophy has been included in secondary Sarcopenia by the Report of the European Working Group on Sarcopenia in Older People 2010 [3]. Disuse muscle atrophy is classified as secondary Sarcopenia, and we often experience it as a result of reduction of activity such as in the case of a clinically bed ridden patient. Zero gravity has been included as a cause of disuse and categorized as secondary Sarcopenia in this 2010 categorization.

    A decrease in muscle volume was reported by 4–16%, and in strength was reported by 9–11% after 5–17 day short-term Space Shuttle flights [46]. 16–28 weeks stays on the Station Mir resulted in changes of 12–20% in volume [7]. It was also reported that volume of the gastrocnemius and soleus muscles decreased by 10% and by 15% respectively, and concomitant peak plantar flexor power decreased by 32% in nine subjects after about 6 months on the International Space Station (ISS) [8].

    Astronauts usually exhibit a decrease in Bone Mineral Density (BMD) in the hip and lumbar spine by 1.0% to 1.5% per month [2,9,10]. This finding highlights the accelerated rate of BMD loss during spaceflight, contrasting remarkably with the typical age related rate of bone loss of 0.5% to 1.0% per year in older individuals on Earth [2]. The risk of fractures is of particular concern upon re-exposure to mechanical loading, such as during the exploration of an unknown planet or return to Earth’s full gravity field. Moreover, cumulative skeletal deconditioning could increase the risk of premature osteoporosis and of fractures later in life.

    Such deteriorations of the musculoskeletal system are one of the main issues for a long term stay in space, and several countermeasures have been developed and their effectiveness reported [1,2,1114]. Concerning these countermeasures, the evidence report of the Human Research Program of NASA described as follows [15]. A very simple exercise device which consisted of nylon cords rotating around a shaft within the cylinder was used on some Apollo missions. After the first manned mission to Skylab 2 (Skylab project was the first United States orbital space station), a commercial device, termed “Mini Gym,” modified extensively and designated “MK-I,” was available to transmit the force on the arms, trunk, and legs. Subsequently developed exercise devices provided loads by extension springs or bungee cords. In the early phase of the ISS program, the interim Resistive Exercise Device which was an elastomer-based resistive exercise hardware was used. A further developed version, called advanced Resistive Exercise Device (ARED) was delivered to ISS in 2010 and is in use now. ARED delivers adjustable loads of up to 600 pounds produced by vacuum canisters to enable a constant force and inertial flywheels to simulate the inertial loads that would be experienced using free weights at 1-G gravity. Thus, the development of countermeasures has advanced, ARED especially has provided good results. However, ARED occupies a large space and is difficult to use on a small spaceship which will be indispensable for missions to the moon, establishment of a lunar base, and interplanetary travel to Mars. Furthermore, there is only one ARED system in ISS, and thus the astronauts on the ISS can’t exercise at the same time. If the ARED breaks down, it is a severe problem.

    We have developed a compact training device named “hybrid training system” (HTS) that is designed to maintain the musculoskeletal system of astronauts by using an electrically stimulated antagonist to resist the volitional contraction of agonist muscles (Fig 1) [1622]. HTS, which utilizes electrically stimulated antagonist force as resistance to joint motion instead of gravity, causes electrically stimulated muscles to provide resistance to the motion of an antagonist muscle undergoing training. In other words, electrical stimulation is applied to the antagonist muscle during joint motion, the electrically stimulated antagonist muscle contracts eccentrically and its tension becomes a resistance to the agonist muscle. During HTS training, both flexion and extension muscles contract simultaneously, and longitudinal force load will be applied on the sandwiched bone by these contracting muscles. Multiple ground-based experiments [1621] and a parabolic flight verification [22] have been encouraging as to the possibility of use by astronauts, but, thus far, evaluation in space has not been conducted.

    In this experiment, as an initial verification on the ISS, HTS was used for one of an astronaut’s upper extremities (the non-dominant arm) for four weeks, and the resulting muscle strength, mass and BMD were compared to those of the non-HTS arm (the dominant arm) to examine its orbital operation capability and utility, as well as the preventive effect of HTS for musculoskeletal atrophy of an astronaut in weightlessness.

    Materials and Methods

    Ethics Statement

    IRB of the Japanese Aerospace Exploration agency: JAXA and National Aeronautics and Space Administration: NASA approved the design of this study protocol. The subject was given oral and written explanations of the study involving the objective of the training method and its risks, and then signed consent forms for participation in this research. The subject was assured that he could discontinue if he wished. The individual of figure in this manuscript has given written informed consent (as outlined in PLOS consent form) to publish these case details.

    Subject

    One of the ISS crew members was a candidate as the subject. The subject was allowed to perform daily operation and usual activities on the ISS including daily exercise and other experiments.

    Equipment

    HTS

    The system was basically the same as those used in previous ground based experiments [1622], however it was designed and manufactured for use in the ISS under the criteria of NASA (Chiyoda Advance Solutions, CHIYODA CORPORATION, Yokohama, Japan). For example, the hardware of the ground model was changed so that harmful gas would not be generated in case of a fire, and the electromagnetic wave produced by the stimulator had no adverse effects on ISS. HTS consists of an electric stimulator, battery, electrodes, motion sensor, and a muscle supporter (Fig 2). The size and weight of the HTS device were 280 mm × 180 mm × 100 mm and 1650 g.

    Stimulator A constant voltage stimulator was used to prevent heat generation caused by impedance increase from deterioration or insufficient setting of the electrodes, and the restriction of electric current was also set to prevent overstimulation during decreasing impedance. The subject can set the stimulation intensity, and has the ability to determine overload for himself. The output of electric current is isolated by a transformer, and the DC component does not apply output to the human body. The maximum current of stimulation applied to the subject does not exceed 20mA in flight. The battery was a Canon BP-930 (Canon Inc. Tokyo Japan), which was already present on the ISS for a video camera. This battery was available for use, and lasts for 15 HTS training sessions when fully charged.

    Electrode

    Gel coated carbon electrodes (SEKISUI CHEMICAL CO.,LTD, Tokyo Japan) were attached over the motor points of the biceps and triceps muscles using a supporter. The supporter was designed so that the subject would be able to set the electrodes at the proper position easily for himself (GOLDWIN INC., Tokyo, Japan).

    Motion sensor

    Joint motion was detected by expansion and retraction of a wire connected to a rotary encoder (ME-20-P, MUOTH ENGINEERING INC., Tokyo, Japan). The resolution, maximal detection speed, and maximal acceleration of the wire-rotary encoder were 0.01 mm, 15 m / min, and 7.8 m / s2, respectively.

    Training protocol

    Put on and set HTS

    The electrodes were embedded in the supporter and attached over the motor points of the triceps and biceps muscles for the non-dominant upper arm only. Stimulation intensity was set at the level predetermined in a ground based adjustment 4 months before launch, and fixed for the ISS experiment. It was determined as 80% of maximal comfortable stimulation intensity as per previous ground based studies [1622]. A constant stimulation intensity was used during the entire 4 week training period, and it was 21.0V on the triceps and 15.5V on the biceps muscle respectively.

    HTS training

    HTS training took place toward the end of the flight, starting at less than return- 7weeks (Fig 3). Reciprocal elbow curls of both upper extremities, 2-seconds of flexion and 2-seconds of extension, were performed. One set of training consisted of 10 elbow curls, and 10 sets of 10 elbow curls with 1 minute rest intervals between sets were performed during a training session. 15 minutes 40 seconds were required for one session. 3 sessions were performed per week for 4 weeks, totaling in 12 sessions of training performed on the ISS.

    Evaluations

    Ground based evaluations

    Ground based evaluations were performed using high quality evaluation devices. Pre-flight evaluations were done 1.5 ± 0.5 months before launch, and post-flight evaluations were done within 7days of return to earth (Fig 3).

    Muscle performance

    Biodex System4-PRO (Biodex Medical Systems, Shirley, New York, USA) was used to evaluate muscle performance at Johnson Space Center. Measurement of elbow extension and flexion force was performed with isokinetic measurement at 180 degrees/min. In the isokinetic measurement, Peak Torque (Nm), Total Work (Joule: amount of work accomplished for the entire set) and Average Power (Watts: Total Work divided by time) were evaluated. Three sets of measurements were performed for the evaluation, and the maximum value was used for evaluation.

    Muscle volume by MRI

    Muscle volume measurement by Magnetic Resonance Imaging (MRI) (SIEMENS MAGNETOM Verio 3T, Washington, D.C., USA) was performed at the Specialty Care Center, Victory Lakes of the University of Texas Medical Branch. A 5mm diameter spherical capsule of vitamin D medicine (Alfarol, CHUGAI PHARMACEUTICAL CO. LTD., Tokyo, Japan) which contained lipid was attached as a marker on the subject’s upper arms to confirm the scan level. A scale formed from an elastic arm support band (GOLDWIN INC., Tokyo, Japan) was made to identify a constant distance from the humeral medial condyle. The arms were scanned bilaterally using T1-weighted images (TR/TE = 500/18 msWeWe). Eleven axial slices of 10mm thickness were prescribed on a coronal scan including the marker and acquired perpendicular to the main axis of the humerus. 3 slices including the center slice with the marker were used to compare muscle volume. A scale was also used for a tape measurement of arm circumference during inflight evaluation.

    DXA

    Dual Energy X-ray Absorptiometry: DXA (Hologic QDR 4500 W DXA scanner, Hologic Inc., MA, USA) was performed at Johnson Space center to evaluate bone mineral density: BMD, lean (muscle) mass and fat mass. DXA data was provided by the NASA data sharing program.

    Inflight evaluations

    Numerical Rating Scale (NRS) was checked by the subject after the first three sessions of training to assess any pain experienced by the subject. Other inflight evaluations were performed using simple evaluation methods 6 days before and 5 days after the 4week training period (Fig 3).

    Isometric peak force

    Muscle force measurement was performed using a hand held dynamometer (HHD) (GT 310, OG Giken, Okayama, Japan) (Fig 4A). HHD was used to evaluate elbow extension and flexion strength. The subject held the HHD himself, and isometric elbow force was measured by HHD as the subject pressed it to the hand rail in an erect position with the subject’s elbow joint at 90 degrees flexion position and feet fixed in a foot rest. For the precise measurement, a wrist fixation supporter and body fixation harness were originally made and utilized. Measurement was performed three times, and the maximum value was used for evaluation.

    Read more https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4546678/

    Newsletter

    Subscribe to our newsletter to receive the latest news about the beauty industry trends, technologies and more.

    Newsletter

    Subscribe to our newsletter to receive the latest news about the beauty industry trends, technologies and more.

    Contact us

    Let’s talk business! Vip Italia team is perfectly equipped to handle your requirements. Describe your needs, and we'll get back to you to discuss how to future-proof your beauty business or get ahead of competition.

    By clicking the "Contact us" button, you agree that Vip Italia will process your personal information in accordance with our Privacy Policy and send you marketing materials. You can unsubscribe at any time.